Noise from Cavitation: Bad for Control Valves(1)

Just as sound can have negative effects on the human body, certain frequencies can play havoc on industrial equipment. When control valves are not selected appropriately, there is an increased risk for cavitation, which causes high noise and vibration levels, resulting in very rapid damage to the valve's internals and/or the downstream piping. In addition, high noise levels usually cause vibration that can damage piping, instruments and other equipment.

 

Negative Effects on Control Valves & Equipment

Along with degraded control capability and rapid deteriation of the control valve itself, valve generated cavitation can cause serious damage to the piping system in which it occurs. Most of this damage is caused by vibrational noise energy, accelerated corrosion, and process contamination.

The high noise levels associated with cavitation reflect the large-amplitude vibrations generated by the formation and collapse of vapor bubbles near and downstream of the vena contracta.

noise from cavitation 2While this normally occurs within the valve body in globe and rotary plug valves, it can actually occur in the piping downstream of a short, high-recovery valve like wafer-body segment (V) ball valves, large ball valves and especially butterfly valves. When these valves are miss-applied in a location prone to cavitation, it is not uncommon for the piping downstream of the valve to be covered with weld-repaired leaks, or for this section of pipe to be frequently replaced as it fails.

Regardless of whether the cavitation occurs inside or downstream of the valve, equipment downstream of the cavitation zone can see extensive damage. The large-amplitude vibrations can excite oscillatory failure in thin diaphragms, springs, and small cross-section or cantilevered structures. Frequent points of failure are found in instrumentation such as pressure gauges and transmitters, thermowells, flow meters, and sampling systems. Heat exchangers can fail prematurely from fatigue as the heat transfer fins oscillate due to vibration. Check valves, actuators, positioners and switches that contain springs will suffer accelerated wear, and mounting brackets, fasteners and couplings will loosen and fail because of the vibration. Unfortunately, hydrodynamic noise propagates extremely well in liquids and metal pipe walls, so it can take hundreds of pipe diameters for the noise to dampen to non-dangerous levels once it occurs.

- See more at: http://www.valvemagazine.com/

Hits:  UpdateTime:2013-11-08 08:38:53  【Printing】  【Close
Previous:No Information
Next:No Information
  • Copyright (c) 2008-2015 Yongjia Goole Valve Co,.Ltd http://www.chinavalveworld.com E-mail: goole4@goolevalve.com
  • Address: He_yi Industrial Zone, Oubei Town, Wenzhou City, Zhejiang Province, P. R. China TEL: 86 - 577 - 57781015 FAX : 86 - 577 - 67985602
  • safety relief valve(our hot), pressure reducing valve and other steam trap,bellow sealed globe valve,ball valve, Y/T/U strainer
Online 
Ms Cathy Ms Cathy MSNMs Cathy